The Hardware includes: (1) Two single-channel power supplies; (2) one Low Voltage Distribution Board (LVDB); (3) Five CFEBs mounted on the test chamber; (4) one production DAQMB under test; (5) one parallel to JTAG converter boxe; (6) one DAQMB data to fiber Ethernet package converter board; (7) one VME crate with Dynatem as controller; (8) fake peripheral crate backplane; (9) computer.
DAQMB Test Firmware SetupThe compatible CFEB firmware is dated to 2003, which is febf_v4_r1, with usercode of "CFEB7041". The DMB firmware is loaded by the production test software.
DAQMB Test Software SetupThe software (includes /root and /home/cmsdmb6 ) is running on cmspc01 computer under linux with username: cmsdmb6. Here is the process to start the DAQMB production test program.
(1) login cmsdmb6, with usual password;
(2) open a terminal, and su (set as superuser);
(3) load drivers by "./setup_fast_daq";
(4) quit the superuser, then "cd fast_daq/daqmb_test";
(5) start the DAQMB test program by "Daqmb";
(6) Enter the DAQMB serial number, then run to start testing
Back to OHIO
STATE CMS home page